-40%

Fluke 115 True RMS Digital Multimeter Brand New

$ 99.79

Availability: 30 in stock
  • Manufacturer Part Number: 115
  • Returns Accepted: Returns Accepted
  • Refund will be given as: Money Back
  • Condition: New
  • Return shipping will be paid by: Buyer
  • Brand: Fluke
  • Warranty: Yes
  • Item must be returned within: 30 Days

    Description

    Designed by electricians. Engineered by Fluke.
    Compact true-rms meter for field service technicians. The Fluke 115 is the solution for a
    wide variety of electrical and electronic testing applications.
    Features:
    Resistance, continuity, frequency, capacitance, and diode test
    Measures 20 A (30 seconds momentary; 10 A continuous)
    Large white LED backlight to work in poorly lit areas
    Compact ergonomic design for one-handed operation
    Compatible with optional magnetic hanger (ToolPak™)
    True-rms for accurate measurements on non-linear loads
    Min/Max/Average with elapsed time to record signal fluctuations
    CAT III 600 V safety rated
    115 Multimeter includes:
    TL75 Test Lead Set
    Holster
    User's Manual
    9V Battery
    Specifications:
    Maximum voltage between any terminal
    and earth ground
    600 V
    Surge protection
    6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2
    Display
    Digital:
    6,000 counts, updates 4 per second
    Bar graph
    33 segments, updates 32 per second
    Operating Temperature
    -10 °C to + 50 °C
    Storage Temperature
    -40 °C to + 60 °C
    Battery type
    9 volt Alkaline, NEDA 1604A/ IEC 6LR61
    Battery Life
    400 hours typical, without backlight
    Accuracy Specifications:
    DC millivolts
    Range:
    Resolution:
    Accuracy:
    600.0 mV
    0.1 mV
    ± ([% of reading] + [counts]): 0.5% + 2
    DC volts
    Range/Resolution:
    Range/Resolution:
    Range/Resolution:
    Accuracy:
    6.000 V / 0.001 V
    60.00 V / 0.01 V
    600.00 V / 0.1 V
    ± ([% of reading] + [counts]): 0.5% + 2
    AC millivolts
    {1}
    true-rms
    Range:
    Resolution:
    Accuracy:
    600.0 mV
    0.1 mV
    1.0 % + 3 (dc, 45 Hz to 500 Hz)
    2.0 % + 3 (500 Hz to 1 kHz)
    AC volts
    {1}
    true-rms
    Range/Resolution:
    Range/Resolution:
    Range/Resolution:
    Accuracy:
    6.000 V / 0.001 V
    60.00 V / 0.01 V
    600.0 V / 0.1 V
    1.0 % + 3 (dc, 45 Hz to 500 Hz)
    2.0 % + 3 (500 Hz to 1 kHz)
    Continuity
    Range:
    Resolution:
    Accuracy:
    600 ?
    1 ?
    Beeper on < 20 ?, off > 250 ?; detects opens or shorts of 500 ?s or longer
    Ohms
    Range/Resolution:
    Range/Resolution:
    Range/Resolution:
    Range/Resolution:
    Range/Resolution:
    Accuracy:
    Range/Resolution:
    Accuracy:
    600.0 ? / 0.1 ?
    6.000 k? / 0.001 k?
    60.00 k? / 0.01 k?
    600.0 k? / 0.1 k?
    6.000 M? / 0.001 M?
    0.9 % + 1
    40.00 M? / 0.01 M?
    5 % + 2
    Diode Test
    Range/Resolution:
    Accuracy:
    2.00 V / 0.001 V
    0.9% + 2
    Capacitance
    Range/Resolution:
    Range/Resolution:
    Range/Resolution:
    Range/Resolution:
    Range/Resolution:
    Accuracy:
    Range/Resolution:
    Accuracy:
    1000 nF / 1 nF
    10.00 ?F / 0.01 ?F
    100.0 ?F / 0.1 ?F
    9999 ?F / 1 ?F
    100 ?F to 1000 ?F
    1.9% + 2
    > 1000 ?F
    5% + 20%
    LoZ capacitance
    Range:
    Accuracy:
    1 nF to 500 ?F
    10% + 2 typical
    AC ?amps true-rms
    (45 Hz to 500 Hz)
    Range/Resolution:
    Range/Resolution:
    Accuracy:
    600.0 A / 0.001 A
    10.00 A / 0.01 A
    1.5% + 3
    20 A overload for 30-seconds max
    DC ?amps
    Range/Resolution:
    Range/Resolution:
    Accuracy:
    600.0 A / 0.001 A
    10.00 A / 0.01 A
    1.0% + 3
    20 A overload for 30-seconds max
    Hz (V or A input)
    [2]
    Range/Resolution:
    Range/Resolution:
    Range/Resolution:
    Range/Resolution:
    Accuracy:
    99.99 Hz / 0.01 Hz
    999.99 Hz / 0.1 Hz
    9.999 Hz / 0.001 Hz
    50.00 Hz / 0.01 Hz
    0.1% + 2
    Notes:
    1)
    All ac voltage ranges except Auto-V/LoZ are specified from 1 % to 100 % of range. Auto-V/LoZ is specified from 0.0 V.
    2)
    Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
    3)
    Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage. Frequency is dc coupled, 45 Hz to 5 kHz for ac current.
    4)
    Temperature Range/Resolution: -40 °F to 752 °F / 0.2 °F
    5)
    Frequency is ac coupled, 5 Hz to 30 kHz for ac voltage.
    Mechanical & General Specifications:
    Size
    167 x 84 x 46 mm (6.57" x 3.31" x 1.82")
    Weight
    550 g
    Warranty
    3 Years
    Track Page Views With
    Auctiva's FREE Counter